TDLR LASH EXTENSION WRITTEN EXAM LATEST 2023 REAL EXAM 200 QUESTIONS AND CORRECT ANSWERS|AGRADE

TDLR LASH EXTENSION WRITTEN EXAM LATEST 2023
REAL EXAM 200 QUESTIONS AND CORRECT
ANSWERS|AGRADE
What would cause the extension to keep turning? – ANSWER- Lash is too heavy
When are you required to removes lashes? – ANSWER- When lashes are loose
What can cause corneal abrasion – ANSWER- Scrapes and scratches
What length is used for natural thinning lashes – ANSWER- .10
What do you do if a client suffers from an open would – ANSWER- Put on gloves
How often do salons get inspections – ANSWER- Every 2 years
How many times should you separate the lashes during lash application? –
ANSWER- 4 times
What is a MSDS – ANSWER- MSDS – Material Safety Data Sheet – provides
detailed information on the hazards of a particular substance

  • Accidental release measures
  • Exposure controls and personal protection
  • Handling and storage
    What is the consequence of demodex mites? – ANSWER- Inflamtion, and itchiness
    along eyelids causes blepharitis, which can lead to madarosis
    After you sanitize your implements where should they be placed? – ANSWERSterilizer, auto clave
    How to perform a path test? – ANSWER- Perform in the inside of the arm,
    providing a basis for judging sensitivity of level of the clients skin
    What do you do with bloody sheeets – ANSWER- Double bag them, put the
    biohazard sticker on the bag and place them in the trash bag and inside of the
    contaminated waste container

What does OSHA stand for? – ANSWER- Occupational Safety and Health
Administration
What do you do with uses sheets – ANSWER- Place them in the dirty laundry
container
List steps of blood exposure incident – ANSWER- 1.Stop the service
2.Put gloves on
3.Apply pressure to the wound with a clean cotton ball or gauze
4.After the bleeding has stopped clean wound with anti-septic powder/wipe
5.Bandage wound with a band-aid
6.Clean and disinfect workstation, use EPA and registered disinfect to clean blood
and bodily fluids
7.Double bag contaminated objects
8.Put a Bio-Hazard sticker on the bag and place it in the trash bag.
9.Then put it in the container for contaminated waste

  1. Also deposit sharp disposals in the sharp box
    11.Make sure all tools have been cleaned thoroughly and immersed in EPA
    registered solution for at least 10 minutes
    How do you clean electrical equipment that can’t be immersed? – ANSWER- All
    electrical equipment must be wiped down or sprayed down with EPA
    How should you store your adhesive – ANSWER- Sealed tight in a cool dark space
    Decontamination #1 – ANSWER- Cleaning and then disinfecting with an
    appropriate EPA registered disinfectant
    Side affects of Rosacea – ANSWER- Redness, red bumps, swollen
    What length should you use for natural thinning lashes? – ANSWER- .10
    Disinfectantion – ANSWER- Using chemicals that kill the most microorganisms
    What length lashes are recommended for protruding eyes? – ANSWER- Short and
    full lashes
    Explain lash removal process? – ANSWER- Apply lash adhesive remover on
    lashes and take them off with microfiber brushes

Leave a Comment

Scroll to Top